Show simple item record

dc.contributor.authorM. J. Tait
dc.contributor.authorN. Isyumov
dc.contributor.authorA. A. El Damatty
dc.date.accessioned2017-05-08T21:00:08Z
dc.date.available2017-05-08T21:00:08Z
dc.date.copyrightFebruary 2007
dc.date.issued2007
dc.identifier.other%28asce%290733-9445%282007%29133%3A2%28251%29.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/34983
dc.description.abstractThe tuned liquid damper (TLD) is increasingly being used as an economical and effective dynamic vibration absorber to mitigate the dynamic response of structures. The ability to design a TLD to operate in two directions simultaneously is particularly attractive. In this paper the results of bidirectional (2D) structure-TLD tests are reported on. These include the free-surface motion, the resulting base shear forces, and the work done by bidirectional tuned liquid dampers (2D TLD) attached to simple structures and response displacements and accelerations of 2D structure-TLD systems. The importance of this experimental study is that it examines 2D structure-TLD behavior over a range of excitation amplitude values covering the practical range of serviceability accelerations for buildings subjected to wind loads. Experimental results are subsequently used to verify the applicability of a unidirectional structure-TLD numerical model to 2D structure-TLD analysis. Findings indicate that the structure-TLD model is capable of describing the structure-TLD response within the range of system response amplitudes experimentally tested.
dc.publisherAmerican Society of Civil Engineers
dc.titleEffectiveness of a 2D TLD and Its Numerical Modeling
dc.typeJournal Paper
dc.journal.volume133
dc.journal.issue2
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)0733-9445(2007)133:2(251)
dc.treeJournal of Structural Engineering:;2007:;Volume ( 133 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record