• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Effect of Supplemental Viscous Damping on the Seismic Response of Structural Systems with Metallic Dampers

    Thumbnail
    View/Open
    %28asce%290733-9445%282007%29133%3A10%281434%29.pdf (2.209Mb)
    Date
    2007
    Author
    Ramiro Vargas
    Michel Bruneau
    Metadata
    Show full item record
    Abstract
    Metallic dampers can enhance structural performance by reducing seismically induced lateral displacements, and by reducing inelastic behavior of beams and columns. Limiting story drift also indirectly allows us to mitigate damage of nonstructural components that are sensitive to lateral deformations. However, many nonstructural elements and components are vulnerable to excessive accelerations. Therefore, in order to protect these components, floor accelerations in buildings should be kept below certain limits. In this perspective, this paper investigates the seismic performance of single-degree-of-freedom (SDOF) systems with metallic and viscous dampers installed in parallel, to determine the effectiveness or appropriateness of using metallic dampers to mitigate lateral displacements, simultaneously with viscous dampers to reduce acceleration demands, knowing that their behavior is fundamentally different (i.e., metallic dampers are displacement dependent, whereas velocity dampers are velocity dependent). The effect of a combination of these damping systems is, therefore, studied for SDOF structures as a contribution to the state-of-the-art of seismic protection of nonstructural components. Parametric analyses investigate the effectiveness of adding various levels of viscous damping on the equivalent hysteretic damping and on the spectral floor acceleration for short, intermediate, and long period structures. Argand diagrams are used to explain why in some instances it is observed that adding viscous dampers to strongly inelastic systems can result in increases in floor acceleration (rather than the intended decreases). Results from this study are also applicable to buildings that have been retrofitted with viscous dampers and whose original frame still behaves inelastically after the retrofit.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/34917
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV