dc.description.abstractHigh temperature exposures were carried out to simulate long-time service. Rupture curves for exposed Grade 11 and Grade 22 steels did not exhibit the instabilities characteristic of the unused materials so that straight-line extrapolation gave good predictions of long-time strengths. Possibly due to a C-type reaction, strength predictions were poorer for Type 304 steel. Similar strengths were obtained using parameter tests of the unused materials. At the present stage of development, simulated service exposures offer an alternative, but not a superior, technique for extrapolating rupture characteristics.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleThe Influence of Simulated Service Exposure on the Rupture Strengths of Grade 11, Grade 22, and Type 304 Steels
dc.typeJournal Paper
dc.journal.volume96
dc.journal.issue1
dc.journal.titleJournal of Engineering Materials and Technology
dc.identifier.doi10.1115/1.3443179
dc.journal.fristpage10
dc.journal.lastpage21
dc.identifier.eissn1528-8889
dc.keywordsSteel
dc.keywordsRupture AND High temperature
dc.treeJournal of Engineering Materials and Technology:;1974:;volume( 096 ):;issue: 001