Show simple item record

dc.contributor.authorJ. M. Steichen
dc.date.accessioned2017-05-09T01:36:26Z
dc.date.available2017-05-09T01:36:26Z
dc.date.copyrightJuly, 1973
dc.date.issued1973
dc.identifier.issn0094-4289
dc.identifier.otherJEMTA8-26833#182_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/163821
dc.description.abstractThe high strain rate tensile properties of solution annealed Type 304 stainless steel have been determined experimentally. Tests were performed at strain rates ranging from 3 × 10−5 to 1 × 102 in./in./sec at temperatures from 600 to 1600 deg F. At temperatures to 1000 deg F, the strength and ductility are largely insensitive to variations in strain rate, whereas at temperatures from 1200 to 1600 deg F, significant increases in both strength and ductility are observed with increasing strain rate.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleHigh Strain Rate Tensile Properties of AISI Type 304 Stainless Steel
dc.typeJournal Paper
dc.journal.volume95
dc.journal.issue3
dc.journal.titleJournal of Engineering Materials and Technology
dc.identifier.doi10.1115/1.3443147
dc.journal.fristpage182
dc.journal.lastpage185
dc.identifier.eissn1528-8889
dc.keywordsStainless steel
dc.keywordsTemperature AND Ductility
dc.treeJournal of Engineering Materials and Technology:;1973:;volume( 095 ):;issue: 003
dc.contenttypeFulltext