Show simple item record

dc.contributor.authorHamouda, Ouajih
dc.contributor.authorWeaver, David S.
dc.contributor.authorRiznic, Jovica
dc.date.accessioned2017-05-09T01:32:49Z
dc.date.available2017-05-09T01:32:49Z
dc.date.issued2016
dc.identifier.issn0094-9930
dc.identifier.otherpvt_138_03_031304.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/162382
dc.description.abstractAn experimental facility was designed and built to study the loading on steam generator tubes during a blowdown. The facility used refrigerant R134a and measurements were taken for static and dynamic pressures as well as tube loading and temperatures. Commissioning experiments indicated that the offtheshelf dynamic pressure transducers and load cells could not take the mechanical and thermal shock loading caused by the blowdown and produced spurious results of no value. This paper presents the instrumentation problems found, explains why they occurred, describes the remedial procedures employed, and outlines the instrumentation validation methodologies developed. The success of the instrumentation development is demonstrated in a series of experiments designed to assess the rapid transient measurement system.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleInstrumentation Development and Validation for an Experimental Two Phase Blowdown Facility
dc.typeJournal Paper
dc.journal.volume138
dc.journal.issue3
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.4032650
dc.journal.fristpage31304
dc.journal.lastpage31304
dc.identifier.eissn1528-8978
dc.treeJournal of Pressure Vessel Technology:;2016:;volume( 138 ):;issue: 003
dc.contenttypeFulltext