• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Medical Devices
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Medical Devices
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    A Biologically Inspired Knee Actuator for a KAFO

    Thumbnail
    View/Open
    med_010_04_045001.pdf (2.126Mb)
    Date
    2016
    Author
    Tian, Feng
    Hefzy, Mohamed Samir
    Elahinia, Mohammad
    Metadata
    Show full item record
    Abstract
    Knee–ankle–foot orthoses (KAFOs) are prescribed to improve abnormal ambulation caused by quadriceps weakness. There are three major types of KAFOs: passive KAFOs, semidynamic KAFOs, and dynamic KAFOs. Dynamic KAFOs are the only type that enables to control knee motions throughout the entire walking gait cycle. However, those available in the market are heavy, bulky, and have limited functionality. The UT dynamic KAFO is developed to allow knee flexion and assist knee extension over the gait cycle by using a superelastic nitinol actuator, which has the potential to reduce volume and weight and reproduce normal knee behavior. In order to match the normal knee stiffness profile, the dynamic actuator consists of two actuating parts that work in the stance and swing phases, respectively. Each actuating part combines a superelastic torsional rod and a torsional spring in parallel. Geometries of the two superelastic rods were determined by matlabbased numerical simulations. The simulation response of the dynamic actuator was compared with the normal knee stiffness, verifying that the proposed design is able to mimic the normal knee performance. The surrounding parts of the dynamic knee joint have then been designed and modeled to house the two actuating parts. The dynamic knee joint was fabricated and mounted on a conventional passive KAFO, replacing its original knee joint on the lateral side. Motion analysis tests were conducted on a healthy subject to evaluate the feasibility of the UT dynamic KAFO. The results indicate that the UT dynamic KAFO allows knee flexion during the swing phase of gait and provides knee motion close to normal.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/162079
    Collections
    • Journal of Medical Devices

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV