Show simple item record

dc.contributor.authorBall, Erick
dc.contributor.authorGarcia, Ephrahim
dc.date.accessioned2017-05-09T01:31:51Z
dc.date.available2017-05-09T01:31:51Z
dc.date.issued2016
dc.identifier.issn1932-6181
dc.identifier.otherht_138_08_081301.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/162071
dc.description.abstractDesigning optimal pneumatic muscles for a particular application requires an accurate model of the hyperelastic bladder and how it influences contraction force. Previous work does not fully explain the influence of bladder prestrain on actuator characteristics. We present here modeling and experimental data on the actuation properties of artificial muscles constructed with varying bladder prestrain and wall thickness. The tests determine quasistatic force–length relationships during extension and contraction, for muscles constructed with unstretched bladder lengths equal to 55%, 66%, and 97% of the stretched muscle length and two different wall thicknesses. Actuator force and maximum contraction length are found to depend strongly on both the prestrain and the thickness of the rubber, making existing models inadequate for choosing bladder geometry. A model is presented to better predict force–length characteristics from geometric parameters, using a novel thickwalled tube calculation to account for the nonlinear elastic properties of the bladder. It includes axial force generated by stretching the bladder lengthwise, and it also describes the hoop stress created by radial expansion of the muscle that partially counteracts the internal fluid pressure exerted outward on the mesh. This effective reduction in pressure affects both axial muscle force and meshonbladder friction. The rubber bladder is modeled as a Mooney–Rivlin incompressible solid. The axial force generated by the mesh is found directly from contact forces rather than from potential energy. Modeling the bladder as a thinwalled tube gives a close match to experimental data on wall thickness, but a thickwalled bladder model is found to be necessary for explaining the effects of prestrain.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleEffects of Bladder Geometry in Pneumatic Artificial Muscles
dc.typeJournal Paper
dc.journal.volume10
dc.journal.issue4
dc.journal.titleJournal of Medical Devices
dc.identifier.doi10.1115/1.4033325
dc.journal.fristpage41001
dc.journal.lastpage41001
dc.identifier.eissn1932-619X
dc.treeJournal of Medical Devices:;2016:;volume( 010 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record