• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Medical Devices
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Medical Devices
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Development of a Soft Pneumatic Sock for Robot Assisted Ankle Exercise

    Thumbnail
    View/Open
    med_010_01_014503.pdf (1.610Mb)
    Date
    2016
    Author
    Low, Fan
    Tan, Hong Han
    Lim, Jeong Hoon
    Yeow, Chen
    Metadata
    Show full item record
    Abstract
    Deep vein thrombosis (DVT) is a severe medical condition that affects many patients around the world, where one of the main causes is commonly associated with prolonged immobilization. Current mechanical prophylaxis systems, such as the compression stockings and intermittent pneumatic compression devices, have yet to show strong efficacy in preventing DVT. The current study aimed to develop a soft pneumatic sock prototype that uses soft extension pneumatic actuators to provide assisted ankle dorsiflexion–plantarflexion motion, so as to prevent the occurrence of DVT. The prototype was evaluated for its efficacy to provide the required dorsiflexion–plantarflexion motion by donning and actuating the prototype on simulated ankle–foot models with various ankle joint stiffness values. Our results showed that the soft extension actuators in the sock prototype provided controllable assisted ankle plantarflexion through actuator extension and ankle dorsiflexion through actuator contraction, where in our study, the actuations extended to 129.9–146.8% of its original length. Furthermore, the sock was able to achieve consistent range of motion at the simulated ankle joint across different joint stiffness values (range of motion: 27.5 آ±â€‰6.0 deg). This study demonstrated the feasibility of using soft extension pneumatic actuators to provide robotassisted ankle dorsiflexion–plantarflexion motion, which will act as an adjunct to physiotherapists to optimize therapy time for bedridden patients and therefore may reduce the risk of developing DVT.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/161988
    Collections
    • Journal of Medical Devices

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV