    Abstract
    It is reported that the operating temperature of an oscillating heat pipe (OHP) at an operating limit is not dependent on the ambient temperature but that the maximum heat transfer is dependent on this. In this study, using different ambient temperature conditions, a 15turn OHP filled with HFC134a as a working fluid was operated until it dries out. The maximum heat transfer was found to vary with changes in the ambient temperature, but the operating temperature at an operating limit, which depends on the filling ratio (FR) of the working fluid, was found to be constant. At the operating limit, the operating temperature decreased with an increase in the FR when the ratio was greater than 50 wt.%. Visualization experiments and calculations were used to confirm that there is an increase in the liquid volume in the OHP in accordance with an increase in the heat input and that ultimately the OHP fills with the liquid, resulting in the failure of OHP operation. In contrast, at the operating limit, when the FR was less than 50%, the operating temperature increased in line with an increase in the FR. In this case, it is assumed that the volume of liquid slugs decreases as the heat input increases, thus causing the OHP to dry out. This theory is explained using a P–V diagram of the working fluid in the OHP. The OHP thermodynamic cycle reaches a saturated liquid or vapor line before it reaches a critical point if a specified volume is shifted from the specified volume at the critical point. The optimum FR for maximum heat transfer is therefore decided by the void ratio at the critical point of the working fluid.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/161709
    Collections
    • Journal of Heat Transfer

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV