Show simple item record

dc.contributor.authorKhan, Fahad
dc.contributor.authorSavilonis, Brian J.
dc.date.accessioned2017-05-09T01:27:55Z
dc.date.available2017-05-09T01:27:55Z
dc.date.issued2016
dc.identifier.issn0195-0738
dc.identifier.othermd_138_07_071402.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/160942
dc.description.abstractThermal energy storage (TES) systems that store sensible heat in liquid media require the use of storage tanks. Spherical tanks require less building material and insulation, which might reduce the overall cost of a TES system while providing structural rigidity. The current study investigates an optimized plate diffuser in a thermocline spherical tank storage system to possibly increase the discharge flow rate without disrupting the thermocline region and without reducing the tank thermal efficiency. For low temperature (10–90 آ°C heat storage applications), such as heating, ventilation, and air conditioning (HVAC) and thermal water desalination, storing hot water in a thermocline system can increase the system thermal efficiency by up to 40% when compared to a fully mixed water tank and reduce the installation cost by 30% compared to a twotank system. This study examines using a spherical tank in a thermocline system for such applications. A computational fluid dynamic (CFD) study simulated the discharge process from a spherical storage tank thermocline water system. Thermocline thickness and temperature profile in the tank were numerically determined for Reynolds number, Re = 600 and Froude number, Fr = 1.2; results were then experimentally validated. A CFD parametric study with (500 < Re < 7500) and (0.5 < Fr < 3.3): (i) determined the influence of tank flow dimensionless numbers (Reynolds, Froude, Richardson, and Archimedes) on thermal efficiency and thermocline thickness, (ii) produced an equation to predict the tank thermal efficiency using flow dimensionless numbers, and (iii) estimated the thermocline region volume occupation as a percentage of the total volume. The study of an optimized plate diffuser produced an equation for thermal efficiency based on Re and Fr numbers and estimated a thermocline volume equal to 15% of total tank volume. Flow rate ramp up by a factor of 3 was possible after the thermocline region was formed without losing tank thermal efficiency.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titlePlate Diffuser Performance in Spherical Tank Thermocline Storage System
dc.typeJournal Paper
dc.journal.volume138
dc.journal.issue5
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.4033503
dc.journal.fristpage52006
dc.journal.lastpage52006
dc.identifier.eissn1528-8994
dc.treeJournal of Energy Resources Technology:;2016:;volume( 138 ):;issue: 005
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record