Show simple item record

dc.contributor.authorMazloum, Youssef
dc.contributor.authorSayah, Haytham
dc.contributor.authorNemer, Maroun
dc.date.accessioned2017-05-09T01:27:54Z
dc.date.available2017-05-09T01:27:54Z
dc.date.issued2016
dc.identifier.issn0195-0738
dc.identifier.otherjert_138_05_052906.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/160937
dc.description.abstractThe largescale production of renewable energy is limited by the intermittence nature of the renewable energy sources. Moreover, the electricity production of the thermal and nuclear power plants is not flexible with the electricity demand. Hence, the integration of energy storage technologies into the grid has become crucial as it creates a balance between supply and demand for electricity and protects thereby the electrical grid. Among the largescale energy storage technologies, a novel adiabatic compressed air energy storage (ACAES) system will be developed in this paper. This storage system is characterized, compared to the conventional compressed air energy storage (CAES) system, by the recovery and the reuse of the compression heat in order to improve the system efficiency and avoid the use of fossil fuel sources. This paper discusses a comparison between the static and dynamic modeling of the ACAES system performed by a computer simulation using “Modelica.â€‌ Unlike the static model, the dynamic model takes into account the mechanical inertia of the turbomachinery (compressors and turbines) as well as the thermal inertia of the heat exchangers. Consequently, it enables studying the flexibility of the storage system and its ability to meet the electrical grid requirements (primary and secondary reserves) by evaluating the duration of the transient states. Furthermore, the comparison between the static and dynamic models permits to estimate the efficiency losses due to the transient evolutions.The results show that the storage system needs more than 2 min before being able to consume all the excess energy available on the electrical grid and more than 5 min before being able to produce all the energy required by the electrical grid. These time frames are due especially to the transient states (startup) of the turbomachines. Finally, the system efficiency is 64.7%, the transient states of the system cause losses of 0.9%. These small losses are explained by the short duration of the transient states relative to that of the steady states (15 hrs).
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleStatic and Dynamic Modeling Comparison of an Adiabatic Compressed Air Energy Storage System
dc.typeJournal Paper
dc.journal.volume138
dc.journal.issue6
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.4033399
dc.journal.fristpage62001
dc.journal.lastpage62001
dc.identifier.eissn1528-8994
dc.treeJournal of Energy Resources Technology:;2016:;volume( 138 ):;issue: 006
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record