Show simple item record

dc.contributor.authorLee, Hyoungsoon
dc.contributor.authorAgonafer, Damena D.
dc.contributor.authorWon, Yoonjin
dc.contributor.authorHoushmand, Farzad
dc.contributor.authorGorle, Catherine
dc.contributor.authorAsheghi, Mehdi
dc.contributor.authorGoodson, Kenneth E.
dc.date.accessioned2017-05-09T01:27:27Z
dc.date.available2017-05-09T01:27:27Z
dc.date.issued2016
dc.identifier.issn1528-9044
dc.identifier.otherep_138_01_010907.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/160805
dc.description.abstractGallium nitride (GaN) highelectronmobility transistors (HEMTs) dissipate high power densities which generate hotspots and cause thermomechanical problems. Here, we propose and simulate GaNbased HEMT technologies that can remove power densities exceeding 30 kW/cm2 at relatively low mass flow rate and pressure drop. Thermal performance of the microcooler module is investigated by modeling both singleand twophase flow conditions. A reducedorder modeling approach, based on an extensive literature review, is used to predict the appropriate range of heat transfer coefficients associated with the flow regimes for the flow conditions. Finite element simulations are performed to investigate the temperature distribution from GaN to parallel microchannels of the microcooler. Singleand twophase conjugate computational fluid dynamics (CFD) simulations provide a lower bound of the total flow resistance in the microcooler as well as overall thermal resistance from GaN HEMT to working fluid. A parametric study is performed to optimize the thermal performance of the microcooler. The modeling results provide detailed flow conditions for the microcooler in order to investigate the required range of heat transfer coefficients for removal of heat fluxes up to 30 kW/cm2 and a junction temperature maintained below 250 آ°C. The detailed modeling results include local temperature and velocity fields in the microcooler module, which can help in identifying the approximate locations of the maximum velocity and recirculation regions that are susceptible to dryout conditions.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleThermal Modeling of Extreme Heat Flux Microchannel Coolers for GaN on SiC Semiconductor Devices
dc.typeJournal Paper
dc.journal.volume138
dc.journal.issue1
dc.journal.titleJournal of Electronic Packaging
dc.identifier.doi10.1115/1.4032655
dc.journal.fristpage10907
dc.journal.lastpage10907
dc.identifier.eissn1043-7398
dc.treeJournal of Electronic Packaging:;2016:;volume( 138 ):;issue: 001
dc.contenttypeFulltext