Show simple item record

dc.contributor.authorShin, Sungtae
dc.contributor.authorTafreshi, Reza
dc.contributor.authorLangari, Reza
dc.date.accessioned2017-05-09T01:27:17Z
dc.date.available2017-05-09T01:27:17Z
dc.date.issued2016
dc.identifier.issn0022-0434
dc.identifier.otherds_138_11_111009.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/160753
dc.description.abstractMyoelectric classification has been widely studied for controlling prosthetic devices and human computer interface (HCI). However, it is still not robust due to external conditions: limb position changes, electrode shifts, and skin condition changes. These issues compromise the reliability of pattern recognition techniques in myoelectric systems. In order to increase the reliability in the limb position effect when a limb position is changed from the position in which the system is trained, this paper proposes a myoelectric system using dynamic motions. Dynamic time warping (DTW) technique was used for the alignment of two different timelength motions, and correlation coefficients were then calculated as a similarity metric to classify dynamic motions. On the other hand, Fisher's linear discriminant analysis was applied on static motions for the purpose of dimensionality reduction and Naأ¯ve Bayesian classifier for classifying the motions. To estimate the robustness to the limb position effect, static and dynamic motions were collected at four different limb positions from eight human subjects. The statistical analysis, ttest (p < 0.05), showed that, for all subjects, dynamic motions were more robust to the limb position effect than static motions when training and validation sets were extracted from different limb positions with the best classification accuracy of 97.59% and 3.54% standard deviation (SD) for dynamic motions compared with 71.85% with 12.62% SD for static motions.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleRobustness of Using Dynamic Motions and Template Matching to the Limb Position Effect in Myoelectric Classification
dc.typeJournal Paper
dc.journal.volume138
dc.journal.issue11
dc.journal.titleJournal of Dynamic Systems, Measurement, and Control
dc.identifier.doi10.1115/1.4033835
dc.journal.fristpage111009
dc.journal.lastpage111009
dc.identifier.eissn1528-9028
dc.treeJournal of Dynamic Systems, Measurement, and Control:;2016:;volume( 138 ):;issue: 011
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record