    Temperature Variation Compensation Using Correlation in Pressure Change Leakage Tests

    Thumbnail
    View/Open
    ds_138_01_011002.pdf (865.0Kb)
    Date
    2016
    Author
    Torigoe, Ippei
    Nakatsuma, Kei
    Ohshima, Yasutaka
    Mizumoto, Ikuro
    Mori, Kazuya
    Metadata
    Show full item record
    Abstract
    The conventional pressure change method used in leakage tests is sensitive to the ambient temperature variation. We propose a new method using a correlation technique to compensate for temperature variation in pressure change leakage detection. In the proposed method, gas within a vessel is compressed in such a sequence that it shows no correlation with the ambient temperature variation. The extent of leakage is estimated from the correlation between the pressure variation in the vessel and the compression sequence signal. Experimental results showed that leakage can be successfully detected by the proposed method without being affected by temperature variation.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/160621
    Collections
    • Journal of Dynamic Systems, Measurement, and Control

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV