| dc.contributor.author | Bartran, David S. | |
| dc.date.accessioned | 2017-05-09T01:23:05Z | |
| dc.date.available | 2017-05-09T01:23:05Z | |
| dc.date.issued | 2015 | |
| dc.identifier.issn | 0094-9930 | |
| dc.identifier.other | pvt_137_04_041201.pdf | |
| dc.identifier.uri | http://yetl.yabesh.ir/yetl/handle/yetl/159482 | |
| dc.description.abstract | A simplified model of a pipe mounted thermowell provides a measure of insight into the design and application of intrusive pipe fittings. A combination of Fourier and Green’s function methods together with a distributed load model of the thermowell/pipe wall interface are used to calculate the support compliance and subsequently the natural frequencies of the thermowell. These are compared with limited though independent calculations. This comparison confirms a profound reduction in natural frequencies for commonly encountered thermowell installations, reductions that should not be ignored where the risk of flowinduced resonance is high. | |
| dc.publisher | The American Society of Mechanical Engineers (ASME) | |
| dc.title | Support Flexibility and Natural Frequencies of Pipe Mounted Thermowells | |
| dc.type | Journal Paper | |
| dc.journal.volume | 137 | |
| dc.journal.issue | 4 | |
| dc.journal.title | Journal of Pressure Vessel Technology | |
| dc.identifier.doi | 10.1115/1.4028863 | |
| dc.journal.fristpage | 41201 | |
| dc.journal.lastpage | 41201 | |
| dc.identifier.eissn | 1528-8978 | |
| dc.tree | Journal of Pressure Vessel Technology:;2015:;volume( 137 ):;issue: 004 | |
| dc.contenttype | Fulltext | |