dc.description.abstractA simplified model of a pipe mounted thermowell provides a measure of insight into the design and application of intrusive pipe fittings. A combination of Fourier and Green’s function methods together with a distributed load model of the thermowell/pipe wall interface are used to calculate the support compliance and subsequently the natural frequencies of the thermowell. These are compared with limited though independent calculations. This comparison confirms a profound reduction in natural frequencies for commonly encountered thermowell installations, reductions that should not be ignored where the risk of flowinduced resonance is high.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleSupport Flexibility and Natural Frequencies of Pipe Mounted Thermowells
dc.typeJournal Paper
dc.journal.volume137
dc.journal.issue4
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.4028863
dc.journal.fristpage41201
dc.journal.lastpage41201
dc.identifier.eissn1528-8978
dc.treeJournal of Pressure Vessel Technology:;2015:;volume( 137 ):;issue: 004