Show simple item record

dc.contributor.authorWang, Yanli
dc.contributor.authorSham, T.
dc.contributor.authorJetter, R. I.
dc.date.accessioned2017-05-09T01:23:03Z
dc.date.available2017-05-09T01:23:03Z
dc.date.issued2015
dc.identifier.issn0094-9930
dc.identifier.otherpvt_137_03_031008.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/159469
dc.description.abstractA twobar thermal ratcheting procedure has been implemented to Alloy 617 at very high temperatures. The procedure is based on two bars tested on two coupled servo hydraulic machines to achieve equal displacement and constant total applied load, mimicking the behavior of a pressurized cylinder subjected to through wall thermal transients. The bars were heated and cooled out of phase to generate thermally induced loading superimposed on a constant mean stress. Scoping test results at slow heating and cooling rates are presented for different mean stresses and thermal histories.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleTwo Bar Thermal Ratcheting for Alloy 617—Part I: Scoping Tests
dc.typeJournal Paper
dc.journal.volume137
dc.journal.issue3
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.4028302
dc.journal.fristpage31008
dc.journal.lastpage31008
dc.identifier.eissn1528-8978
dc.treeJournal of Pressure Vessel Technology:;2015:;volume( 137 ):;issue: 003