dc.description.abstractTemperature fluctuations caused by the mixing of hot and cold streams at tee junctions may lead to high cycle thermal fatigue (HCTF) failure. It is necessary to evaluate the integrity of structures where the HCTF may occur. Therefore, the Japan Society of Mechanical Engineers (JSME) published “Guideline for Evaluation of High Cycle Thermal Fatigue of a Pipe (JSME S017),â€‌ in 2003, which provides the procedures and methods for evaluating the integrity of structures with the potential for HCTF. In JSME S017, one of the important procedures of thermal fatigue evaluation is to classify the flow patterns at tee junctions, because the degree of thermal fatigue damage is closely related to the flow pattern downstream of the mixing junction. The conventional characteristic equations for classifying flow patterns are only applicable to 90deg tee junctions (Tjunctions). However, angled tee junctions other than 90 deg (Yjunctions) are also used in chemical plants and refineries for reducing the pressure drop in the mixing zone and for weakening the force of the impingement of the branch pipe stream against the main pipe. The aim of this paper is to develop general characteristic equations applicable to both Tand Yjunctions. In this paper, general characteristic equations have been proposed based on the momentum ratio for all angles of tee junctions. Further, the validity of the proposed characteristic equations and their applicability to all angles of tee junctions have been confirmed using computational fluid dynamics (CFD) simulations. The results have also highlighted that the angle of the branch pipe has a significant effect on increasing the velocity ratio range for less damaging deflecting jet flow pattern, which is an important finding that could be used to extend the current design options for piping systems where HCTF may be a concern. In addition, categorization 3 is recommended as a more proper method for classifying flow patterns at tee junctions when evaluating the potential for thermal fatigue.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleClassification of Flow Patterns in Angled T Junctions for the Evaluation of High Cycle Thermal Fatigue
dc.typeJournal Paper
dc.journal.volume137
dc.journal.issue2
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.4027903
dc.journal.fristpage21301
dc.journal.lastpage21301
dc.identifier.eissn1528-8978
dc.treeJournal of Pressure Vessel Technology:;2015:;volume( 137 ):;issue: 002