dc.contributor.authorSaha, Ritabrata
dc.contributor.authorSen, Swarnendu
dc.contributor.authorMookherjee, Saikat
dc.contributor.authorGhosh, Koushik
dc.contributor.authorMukhopadhyay, Achintya
dc.contributor.authorSanyal, Dipankar
dc.date.accessioned2017-05-09T01:20:05Z
dc.date.available2017-05-09T01:20:05Z
dc.date.issued2015
dc.identifier.issn0022-1481
dc.identifier.otherht_137_12_121010.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/158603
dc.description.abstractExperimental and numerical analyses are carried out for a natural circulation loop (NCL) under low and moderate heater power. The effect of ambient temperature variation on the loop thermal behavior has been taken into account in present study. The effect of liquid inertia has a role in the initial transience, as revealed by the numerical and experimental observations. The steadystate results from the present analyses are validated with the reported dimensionless results for NCL. The experimental steadystate results are in fair agreement with the developed lumped numerical models. At moderate power, the numerical and experimental results indicate periodic oscillations.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleExperimental and Numerical Investigation of a Single Phase Square Natural Circulation Loop
dc.typeJournal Paper
dc.journal.volume137
dc.journal.issue12
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4030926
dc.journal.fristpage121010
dc.journal.lastpage121010
dc.identifier.eissn1528-8943
dc.treeJournal of Heat Transfer:;2015:;volume( 137 ):;issue: 012
dc.contenttypeFulltext