Show simple item record

dc.contributor.authorQayoum, Adnan
dc.contributor.authorPanigrahi, P. K.
dc.date.accessioned2017-05-09T01:20:04Z
dc.date.available2017-05-09T01:20:04Z
dc.date.issued2015
dc.identifier.issn0022-1481
dc.identifier.otherht_137_12_121004.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/158596
dc.description.abstractThis investigation reports the combined effect of synthetic jet and a surfacemounted rib on heat transfer in a square crosssection channel flow. The rib height to hydraulic diameter ratio is equal to 0.1625. The Reynolds number of the channel has been set equal to 5500. The synthetic jet actuator has been operated at different actuation voltages with different amplitude modulation frequencies. At actuation voltage of 55 V, the maximum overall heat transfer is enhanced by 132.6% compared with smooth duct flow.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleCombined Influence of Synthetic Jet and Surface Mounted Rib on Heat Transfer in a Square Channel
dc.typeJournal Paper
dc.journal.volume137
dc.journal.issue12
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4030918
dc.journal.fristpage121004
dc.journal.lastpage121004
dc.identifier.eissn1528-8943
dc.treeJournal of Heat Transfer:;2015:;volume( 137 ):;issue: 012
dc.contenttypeFulltext