Show simple item record

dc.contributor.authorCohen, Ellann
dc.contributor.authorGlicksman, Leon
dc.date.accessioned2017-05-09T01:19:50Z
dc.date.available2017-05-09T01:19:50Z
dc.date.issued2015
dc.identifier.issn0022-1481
dc.identifier.otherht_137_08_081601.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/158528
dc.description.abstractThe thermal conductivity of silica aerogel developed in this research program was measured using the transient hotwire technique. The thermal conductivity of monolithic samples drops significantly from 9.3 mW/m آ·â€‰K to 3.2 mW/m آ·â€‰K with modest pressure reduction from 1 atm to 0.1 atm. The same aerogel in granular form has a thermal conductivity of 15.0 mW/m آ·â€‰K at ambient gas pressure with a modest compression applied to compact the granules and reduce the air void sizes. Radiation heat transfer in the hotwire test may not be representative of its contribution in large scale applications. Measurements of the monochromatic extinction coefficient over the wavelengths of interest resulted in a Rosseland mean extinction coefficient of 2400 m−1 at 300 K. The small thermal penetration distance during the hotwire measurements suggest that in actual use radiation could contribute approximately 2.5 mW/m آ·â€‰K with a possible upper limit of 3.0 mW/m آ·â€‰K to the effective thermal conductivity over that measured using the transient hotwire method.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleThermal Properties of Silica Aerogel Formula
dc.typeJournal Paper
dc.journal.volume137
dc.journal.issue8
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4028901
dc.journal.fristpage81601
dc.journal.lastpage81601
dc.identifier.eissn1528-8943
dc.treeJournal of Heat Transfer:;2015:;volume( 137 ):;issue: 008
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record