Show simple item record

dc.contributor.authorLigrani, Phil
dc.contributor.authorGoodro, Matt
dc.contributor.authorFox, Michael D.
dc.contributor.authorMoon, Hee
dc.date.accessioned2017-05-09T01:19:35Z
dc.date.available2017-05-09T01:19:35Z
dc.date.issued2015
dc.identifier.issn0022-1481
dc.identifier.otherht_137_03_032201.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/158443
dc.description.abstractThe present experimental investigation considers a full coverage film cooling arrangement with different streamwise static pressure gradients. The film cooling holes in adjacent streamwise rows are staggered with respect to each other, with sharp edges and streamwise inclination angles of 20 deg with respect to the liner surface. Data are provided for turbulent film cooling, contraction ratios of 1 and 4, blowing ratios (BRs) (at the test section entrance) of 2.0, 5.0, and 10.0, a coolant Reynolds number of 12,000, freestream temperatures from 75 آ°C to 115 آ°C, a film hole diameter of 7 mm, and density ratios from 1.15 to 1.25. Nondimensional streamwise and spanwise film cooling hole spacings, X/D and Y/D, are 18 and 5, respectively. Data illustrating the effects of contraction ratio, BR, and streamwise location on local, lineaveraged, and spatially averaged adiabatic film effectiveness data; and on local, lineaveraged and spatially averaged heat transfer coefficient data are presented. Varying BR values are present along the length of the contraction passage, which contains the cooling hole arrangement, when contraction ratio is 4. Dependence on BR indicates important influences of coolant concentration and distribution. For example, lineaveraged and spatially averaged adiabatic effectiveness data show vastly different changes with BR for the configurations with contraction ratios of 1 and 4. In addition, much larger effectiveness alterations are present as BR changes from 2.0 to 10.0, when significant acceleration is present and Cr = 4 (in comparison with the Cr = 1 data).
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleFull Coverage Film Cooling: Heat Transfer Coefficients and Film Effectiveness for a Sparse Hole Array at Different Blowing Ratios and Contraction Ratios
dc.typeJournal Paper
dc.journal.volume137
dc.journal.issue3
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4029168
dc.journal.fristpage32201
dc.journal.lastpage32201
dc.identifier.eissn1528-8943
dc.treeJournal of Heat Transfer:;2015:;volume( 137 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record