• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Heat Transfer
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Heat Transfer
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    The New Mathematical Models for Plain Fin and Tube Heat Exchangers With Dehumidification

    Thumbnail
    View/Open
    ht_137_03_031801.pdf (1.013Mb)
    Date
    2015
    Author
    Pirompugd, Worachest
    Wang, Chi
    Wongwises, Somchai
    Metadata
    Show full item record
    Abstract
    For evaluating performance of finandtube heat exchangers under dehumidifying conditions, the recent lumped approach models are based on the enthalpy potential or equivalent dry bulb temperature. This study proposes a new lumped approach model based on the dry bulb temperature difference. The concept of dry bulb temperature was first presented by McQuiston for derivation of fin efficiency under dehumidifying conditions in 1975. This concept is simpler than the concepts of enthalpy potential and equivalent dry bulb temperature. Nevertheless, it cannot be found that this concept is applied to the finandtube heat exchangers. Moreover, this study also presents the finite circular fin method (FCFM) based on the dry bulb temperature and equivalent dry bulb temperature. The FCFM was first presented in our published literature but it was based on the enthalpy potential. The FCFM is done by dividing the finandtube heat exchanger into many small segments. Then, the segments are divided into three cases: fully dry condition, fully wet condition, and partially wet condition. From the results, the new lumped approach model based on dry bulb temperature gives a good result. It is the simplest method for evaluating heat transfer performance of finandtube heat exchangers under fully wet conditions. For the FCFM, the heat and mass transfer characteristics obtained by dry bulb temperature and equivalent dry bulb temperature are nearly the same as those obtained by the enthalpy potential. However, the heat and mass transfer characteristics by the FCFM based on equivalent dry bulb temperature are higher than those obtained by the FCFM based on dry bulb temperature. This is because of the effect of the nonconstant term in the two methods. The correlations applicable for both fully wet and partially wet conditions for the FCFMs based on equivalent dry bulb temperature and dry bulb temperature are proposed to describe the heat and mass transfer characteristics for the present plain fin configuration.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/158441
    Collections
    • Journal of Heat Transfer

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV