Show simple item record

dc.contributor.authorMaddox, John F.
dc.contributor.authorKnight, Roy W.
dc.contributor.authorBhavnani, Sushil H.
dc.date.accessioned2017-05-09T01:17:03Z
dc.date.available2017-05-09T01:17:03Z
dc.date.issued2015
dc.identifier.issn1528-9044
dc.identifier.otherep_137_03_031015.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/157705
dc.description.abstractThe local surface temperature, heat flux, heat transfer coefficient, and Nusselt number were measured for an inline array of circular, normal jets of singlephase, liquid water impinging on a copper block with a common outlet for spent flow, and an experimental twodimensional (2D) surface map was obtained by translating the jet array relative to the sensors. The effects of variation in jet height, jet pitch, confining wall angle, and average jet Reynolds number were investigated. A strong interaction between the effects of the geometric parameters was observed, and a 5 deg confining wall was seen to be an effective method of managing the spent flow for jet impingement cooling of power electronics. The maximum average heat transfer coefficient of 13,100 W/m2 K and average Nusselt number of 67.7 were measured at an average jet Reynolds number of 14,000.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleLiquid Jet Impingement With an Angled Confining Wall for Spent Flow Management for Power Electronics Cooling With Local Thermal Measurements
dc.typeJournal Paper
dc.journal.volume137
dc.journal.issue3
dc.journal.titleJournal of Electronic Packaging
dc.identifier.doi10.1115/1.4030953
dc.journal.fristpage31015
dc.journal.lastpage31015
dc.identifier.eissn1043-7398
dc.treeJournal of Electronic Packaging:;2015:;volume( 137 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record