    Optimal Determination of Respiratory Airflow Patterns for a General Multicompartment Lung Mechanics System With Nonlinear Resistance and Compliance Parameters

    Thumbnail
    View/Open
    ds_137_12_121014.pdf (1.053Mb)
    Date
    2015
    Author
    Paul Hou, Saing
    Meskin, Nader
    Haddad, Wassim M.
    Metadata
    Show full item record
    Abstract
    In this paper, we develop a framework for determining optimal respiratory airflow patterns for a multicompartment lung mechanics system with nonlinear resistance and compliance parameters. First, a nonlinear multicompartment lung mechanics model that accounts for nonlinearities in both the airway resistances and the lung compliances is developed. In particular, we assume that the resistive losses are characterized by a Rohrertype model with resistive losses defined as the sum of linear and quadratic terms of the airflow. The proposed model is more realistic than those presented in the literature, since it takes into account the heterogeneity of lung anatomy and function as well as the nonlinearity of lung resistance and compliance parameters. This model can be used to provide a better understanding of pulmonary function as well as the process of mechanical ventilation. Next, using the proposed nonlinear multicompartment lung model, we develop a framework for determining optimal respiratory airflow patterns. Specifically, an optimization criterion that involves the minimization of the oxygen consumption of the lung muscles and lung volume acceleration for the inspiratory phase, and the minimization of the elastic potential energy and rapid airflow rate changes for the expiratory phase is formulated and solved. The solution to the formulated optimization problem is derived using classical calculus of variation techniques. Finally, several illustrative numerical examples are presented to illustrate the efficacy of the proposed nonlinear multicompartment lung model and the corresponding optimal airflow patterns. Comparison with experimental data shows that our nonlinear resistance model predicts the airflow patterns more accurately than linear resistance models. Moreover, the optimization criterion used in this paper also provides a more accurate prediction of the optimal airflow patterns.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/157657
    Collections
    • Journal of Dynamic Systems, Measurement, and Control

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV