Show simple item record

dc.contributor.authorSoliman, Islam M.
dc.contributor.authorTait, Michael J.
dc.contributor.authorEl Damatty, Ashraf A.
dc.date.accessioned2017-05-09T01:16:46Z
dc.date.available2017-05-09T01:16:46Z
dc.date.issued2015
dc.identifier.issn0022-0434
dc.identifier.otherds_137_11_111001.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/157624
dc.description.abstractImplementation of supplemental damping systems (e.g., the dynamic vibration absorbers (DVAs)) to mitigate excessive tall building vibrations induced by external dynamic loads (wind storms or earthquakes) has increased over the last several decades. A tuned liquid damper (TLD) is a specific type of the DVAs that consists of a rigid tank which is partially filled with a liquid, usually water. The sloshing liquid inside the tank provides inertia forces that counteract the forces acting on the structure, thus reducing the building motion. A single sway mode of vibration is usually targeted, however, for certain structures multiple modes may need to be suppressed. Moreover, the location of the TLD on the floor plate is important for certain modes, such as a torsionally dominate mode. In this paper, a threedimensional (3D) finite element (FE) structureTLD system model (3DstructureTLD) is proposed where the TLDs can be positioned at any location on the structure allowing the most effective positions in reducing the structure's dynamic response to be determined. Therefore, the response of a 3D structure (tower, highrise building, bridge, etc.) fitted with single or multiple TLD(s) and subjected to dynamic excitation can be predicted using the proposed FE model. For torsionally sensitive structure (eccentric/irregular structures), this type of 3D numerical analysis is highly recommended. Two nonlinear TLD models are employed to simulate the TLD and implemented in the FE model. The 3DstructureTLD system model is validated for the cases of sinusoidal and random excitation forces using existing experimental test values. Results from the 3DstructureTLD system model are found to be in excellent agreement with values obtained from experimental tests.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleDevelopment and Validation of Finite Element Structure Tuned Liquid Damper System Models
dc.typeJournal Paper
dc.journal.volume137
dc.journal.issue11
dc.journal.titleJournal of Dynamic Systems, Measurement, and Control
dc.identifier.doi10.1115/1.4030866
dc.journal.fristpage111001
dc.journal.lastpage111001
dc.identifier.eissn1528-9028
dc.treeJournal of Dynamic Systems, Measurement, and Control:;2015:;volume( 137 ):;issue: 011
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record