• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Micro and Nano
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Micro and Nano
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Evaluation of Cutting Forces During Single Pass Microtrenching of Poly (Methyl Methacrylate)

    Thumbnail
    View/Open
    jmnm_002_04_041003.pdf (1.190Mb)
    Date
    2014
    Author
    James, Thomas P.
    Eckman, Nathaniel B.
    Sagar, Amrit
    Saigal, Anil
    Metadata
    Show full item record
    Abstract
    Research was conducted to evaluate a microtrenching process to create microchannels on the surface of poly (methyl methacrylate) (PMMA) for applications in tissue engineering. Experiments with a trenching tool included an exaggerated cutting edge radius (48 خ¼m) to study the impact of a highly negative effective rake angle on forces during single pass microtrenching at subradius cutting conditions. During microtrenching, forces were measured by dynamometer and compared to a finite element (FE) model using an elasticperfectly plastic material model for an undeformed chip thickness from 9 to 64 خ¼m. During experiments, cutting was first observed when the ratio of undeformed chip thickness to cutting edge radius was 0.33. Measured and predicted values of thrust force exceeded cutting force up to an undeformed chip thickness equivalent to the cutting edge radius. The FE model predicted a linear trend in cutting force with feed (r = 0.99) and was substantiated by linear regression of experimental data (r = 0.99). However, at lower values of feed the model overestimated force, with a maximum difference of 42% at a feed of 22 خ¼m. Thrust force was also predicted to be linear (r = 0.99), but at greater feed the experiments indicated a nonlinear decline in thrust force, resulting in a maximum difference of 27% at 64 خ¼m. Finally, an analysis of nodal velocity plots from the FE model revealed a material stagnation zone developed along the cutting edge, rising from the workpiece surface in proportion to feed and then remaining fixed at 63 deg (stagnation angle) for all feeds greater than 35 خ¼m. While the application of an elasticperfectly plastic material model for PMMA was sufficient to predict microtrenching forces by the FE method, differences between predicted and measured thrust forces at greater undeformed chip thickness implies a more complex rheological model may add value.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/156013
    Collections
    • Journal of Micro and Nano

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV