• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Heat Transfer
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Heat Transfer
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Experimental Investigation of the Heat Transfer Performance of a Hybrid Cooling Fin Thermosyphon

    Thumbnail
    View/Open
    ht_136_10_104502.pdf (372.6Kb)
    Date
    2014
    Author
    Pappas, Christina A.
    Jordan, Donald A.
    Norris, Pamela M.
    Metadata
    Show full item record
    Abstract
    The effect of fill volume on the heat transfer performance of a hybrid cooling fin thermosyphon, characterized by an airfoil crosssectional shape and a slotshaped cavity, is investigated. The performance was examined at three fill volumes, expressed as a percentage of the evaporator section: 0%, 60%, and 240%. These were chosen to represent three distinct regimes: unfilled, filled, and overfilled evaporator sections, respectively. The cross section of this copper–water thermosyphon has a NACA0010 shape with a chord length of 63.5 mm and an aspect ratio (ratio of the length of the evaporator section to the cavity width) of 1.109. The evaporator length comprises 8.3% of the total thermosyphon length. The aircooled condenser section was placed in a uniform air flow in the test section of an open return wind tunnel. The rate of heat transfer, or performance, was measured as a function of fill volume and evaporator temperature. The heat transfer performance increased by 100–170% by adding 0.86 ml of working fluid (deionized water), i.e., when the fill volume increased from 0% to 60%, which illustrates the improvement of a cooling fin's heat transfer rate by converting it to a hybrid cooling fin thermosyphon. Of the fill volumes investigated, the thermosyphon achieves a maximum heat transfer rate and highest average surface temperature at the 60% fill volume. Overfilling the evaporator section at 240% fill results in a slight decrease in performance from the 60% fill volume. The results of this study demonstrate the feasibility of hybridizing a cooling fin to act both as a cooling fin and a thermosyphon.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/155394
    Collections
    • Journal of Heat Transfer

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV