Show simple item record

dc.contributor.authorKoptelov, Roman
dc.contributor.authorMalikov, German
dc.contributor.authorLisienko, Vladimir
dc.contributor.authorViskanta, Raymond
dc.date.accessioned2017-05-09T01:09:31Z
dc.date.available2017-05-09T01:09:31Z
dc.date.issued2014
dc.identifier.issn0022-1481
dc.identifier.otherht_136_07_074502.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/155310
dc.description.abstractAn algorithm for choosing the number of quadrature nodes before calculation of a view factor is proposed. Simple criterion is introduced that allows one to estimate the error in the computed view factor. The algorithm allows one to save much computation time by always using the minimum number of nodes for each pair of surface zones and insures a desired accuracy. The algorithm is applied for model of a continuous furnace and is compared with a standard method which uses predefined number of nodes at each surface. The proposed algorithm is many times faster and also more accurate than the standard one.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleAccelerated Method for Surface View Factor Evaluation Based on Error Estimation
dc.typeJournal Paper
dc.journal.volume136
dc.journal.issue7
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4027251
dc.journal.fristpage74502
dc.journal.lastpage74502
dc.identifier.eissn1528-8943
dc.treeJournal of Heat Transfer:;2014:;volume( 136 ):;issue: 007
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record