Show simple item record

dc.contributor.authorCohen, Ellann
dc.contributor.authorGlicksman, Leon
dc.date.accessioned2017-05-09T01:09:19Z
dc.date.available2017-05-09T01:09:19Z
dc.date.issued2014
dc.identifier.issn0022-1481
dc.identifier.otherht_136_04_041301.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/155227
dc.description.abstractWhen the transient hotwire method is used to measure the thermal conductivity of very low thermal conductivity silica aerogel (in the range of 10 mW/mآ·K at 1 atm) end effects due to the finite wire size and radiation corrections must be considered. An approximate method is presented to account for end effects with realistic boundary conditions. The method was applied to small experimental samples of the aerogel using different wire lengths. Initial conductivity results varied with wire length. This variation was eliminated by the use of the end effect correction. The test method was validated with the NIST (National Institute of Standards and Technology) Standard Reference Material 1459, fumed silica board to within 1 mW/mآ·K. The aerogel is semitransparent. Due to the small wire radius and short transient, radiation heat transfer may not be fully accounted for. In a full size aerogel panel radiation will augment the phonon conduction by a larger amount.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleAnalysis of the Transient Hot Wire Method to Measure Thermal Conductivity of Silica Aerogel: Influence of Wire Length, and Radiation Properties
dc.typeJournal Paper
dc.journal.volume136
dc.journal.issue4
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4025921
dc.journal.fristpage41301
dc.journal.lastpage41301
dc.identifier.eissn1528-8943
dc.treeJournal of Heat Transfer:;2014:;volume( 136 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record