Show simple item record

dc.contributor.authorLee, Seung
dc.contributor.authorSkorpenske, Harley
dc.contributor.authorStoica, Alexandru D.
dc.contributor.authorAn, Ke
dc.contributor.authorWang, Xun
dc.contributor.authorNoyan, I. C.
dc.date.accessioned2017-05-09T01:09:16Z
dc.date.available2017-05-09T01:09:16Z
dc.date.issued2014
dc.identifier.issn0022-1481
dc.identifier.otherht_136_03_031302.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/155207
dc.description.abstractA noncontact, nondestructive neutron diffraction technique for measuring thermal resistance of buried material interfaces in bulk samples, inaccessible to thermocouple measurements, is described. The technique uses spatially resolved neutron diffraction measurements to measure temperature, and analytical or numerical methods to calculate the corresponding thermal resistance. It was tested at the VULCAN instrument of the Spallation Neutron Source, Oak Ridge National Laboratories on a stack of three 6061 alloy aluminum plates (heatsource, middleplate, and heatsink), held in dry thermal contact, at low pressure, in ambient air. The results agreed with thermocouplebased measurements. This technique is applicable to all crystalline materials and most interface configurations, and it can be used for the characterization of thermal resistance across interfaces in actual engineering parts under nonambient conditions and/or in moving/rotating systems.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleMeasurement of Interface Thermal Resistance With Neutron Diffraction
dc.typeJournal Paper
dc.journal.volume136
dc.journal.issue3
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4025500
dc.journal.fristpage31302
dc.journal.lastpage31302
dc.identifier.eissn1528-8943
dc.treeJournal of Heat Transfer:;2014:;volume( 136 ):;issue: 003
dc.contenttypeFulltext