dc.description.abstractThe purpose of this study is to evaluate the maximum energysaving potential of residential energy supply systems consisting of a solid oxide fuel cell (SOFC) cogeneration system (CGS) combined with a solar cell (SC) and a battery (BT), compared with a reference system (RS). This study applies an optimization theory into an operational planning problem to measure actual energy demands over the course of 1 year. Eight different types of energy supply system were compared with each other by changing the components of the SOFCCGS, SC, BT, and RS. Meaningful numerical results are obtained, indicating the maximum potential energy savings.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleEnergy Saving Evaluation of SOFC Cogeneration Systems With Solar Cell and Battery
dc.typeJournal Paper
dc.journal.volume11
dc.journal.issue6
dc.journal.titleJournal of Fuel Cell Science and Technology
dc.identifier.doi10.1115/1.4028948
dc.journal.fristpage61006
dc.journal.lastpage61006
dc.identifier.eissn2381-6910
dc.treeJournal of Fuel Cell Science and Technology:;2014:;volume( 011 ):;issue: 006