Show simple item record

dc.contributor.authorRashidi, Majid
dc.contributor.authorKadambi, Jaikrishnan R.
dc.contributor.authorKerze, David
dc.date.accessioned2017-05-09T01:07:04Z
dc.date.available2017-05-09T01:07:04Z
dc.date.issued2014
dc.identifier.issn0195-0738
dc.identifier.otherjert_136_02_021202.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/154536
dc.description.abstractA wind tower system having a three dimensional heliacal wind deflecting structure is studies in this work. The purpose of the helical structure is to increase the natural wind speed and direct the follow of the wind toward two columns of horizontalaxis rooftopsize wind turbines that are installed in the grooves of the helical structure, diametrically opposed to each other. Computational fluid dynamics analyses were conducted to determine the influence of the helical structure on the wind speed reaching the turbines. A wind speed amplification coefficient was determined for a helical structure of 6.7 m outer diameter. The velocity profiles of the wind flow around the helical structure were determined under a postulated wind speed of 4.47 m/s. The flow was modeled as turbulent with a Reynolds Number of 2,052,167. Standard “k–خµâ€‌ turbulent model with “near wall treatmentâ€‌ and “standard wall functionâ€‌ were adapted in all analysis. A “y+â€‌ value of 50 was held constant in all simulation. The gridsize effects on the accuracy of the results were examined. Convergence criterion was satisfied in each case. This study shows that the helical structure having an outer diameter of 6.7 m results in an average wind speed increase factor of 1.52. An experimental wind tower system was fabricated and installed at an elevation of 40 m above the ground. The wind tower system comprised of four identical rooftop size wind turbines, each having 1.6 KW nameplaterating. A helical wind deflecting structure of 11 m tall, and 7 m in major diameter was used in fabrication of the tower. An active yawcontrol mechanism was used to orient the tower into the prevailing wind. The experimental results show that as the result of the use of the wind deflecting structure, an average power amplification factor of 4.69 was obtained for the tower, in comparison with the standard standalone installation of the four wind turbines.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleWind Tower System With a Helical Wind Deflecting Structure, Computational Fluid Dynamics, and Experimental Studies
dc.typeJournal Paper
dc.journal.volume136
dc.journal.issue2
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.4025409
dc.journal.fristpage21202
dc.journal.lastpage21202
dc.identifier.eissn1528-8994
dc.treeJournal of Energy Resources Technology:;2014:;volume( 136 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail
This item appears in the following Collection(s)

Show simple item record