Active Control of Fluid Pressure Pulsation in Hydraulic Pipe System by Bilateral Overflow of Piezoelectric Direct Drive Slide Valve
View/ Open
Date
2014Author
Changbin, Guan
Zongxia, Jiao
Shuai, Wu
Yaoxing, Shang
Fanggang, Zheng
Metadata
Show full item recordAbstract
In this paper, a novel active control of fluid pressure pulsation (ACFPP) is proposed, which meets the need of the highpressure and highspeed hydraulic pipe system. A piezoelectric directdrive slide valve (PDDSV) is designed and used as the active vibration absorber. Two ports of the PDDSV both connect to a bypass near the pump outlet and the other two ports both connect to the oil tank. By the bilateraloverflow through the shoulder of the PDDSV, the overflow wave generated in one cycle of spool motion can cancel two cycles of flow ripple. An adaptiveoptimum control method based on the rotatevector optimization method (RVOM) is adopted to adjust the control parameters in order to minimize the amplitude of the pressure pulsation. The biggest advantage of the proposed ACFPP is that it can eliminate the pressure pulsation when PDDSV only works at half of the pressure pulsation's frequency. The simulation and experimentation both verify the proposed ACFPP. By the proposed ACFPP, the suppression for the singlefrequency component and dualfrequency components of the pressure pulsation have been both realized.