    The Danger of Piping Failure Due to Acoustic Induced Fatigue in Infrequent Operations: Two Case Studies

    Thumbnail
    View/Open
    pvt_135_06_064501.pdf (1.542Mb)
    Date
    2013
    Author
    Mohammed Al
    Ibrahim Al
    Al
    Metadata
    Show full item record
    Abstract
    Failure in piping due to acousticinduced fatigue can be considered catastrophic as it could happen only after a few minutes of operation. Acousticinduced fatigue occurs mainly in gas piping systems with high velocity where high energy is dissipated through pressure reducing stations and pipe branch connections. It usually results in pipe through wall longitudinal cracks, pipe detachment from saddle supports, and complete shear off of branch connections. There are existing design criteria to avoid acousticinduced fatigue based on comparison of generated power level to an acceptable power level. This criterion is normally used for the design of pressure relief and flare piping where high gas velocity exceeding 50% of the speed of sound (i.e., 0.5 Mach) is expected. However, acousticinduced fatigue has been experienced in systems due to intermittent operations. Two case studies are presented in this paper. The first one is during a steamout operation to clean a newly constructed steam header. During the cleaning operation, an orifice plate was used to control the flow in the steam header. Several pipe vents and drains failed due to fatigue in less than 1 h. The second case is for drainage of compressed natural gas during process upset condition. Because of the high level buildup in the liquefied gas separator vessel, the drain valve was opened to release the pressurized liquefied gas to the relief system to reduce the level buildup. Wall cracks and several pipe support detachments were found in the system after the upset condition. This paper presents the engineering analysis and material failure analysis conducted to find the root causes of the failures. Moreover, it highlights the recommendations and lessons learned from these two failures.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/153116
    Collections
    • Journal of Pressure Vessel Technology

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV