Show simple item record

dc.contributor.authorPersoons, Tim
dc.contributor.authorBalgazin, Kuanysh
dc.contributor.authorBrown, Karl
dc.contributor.authorMurray, Darina B.
dc.date.accessioned2017-05-09T01:00:07Z
dc.date.available2017-05-09T01:00:07Z
dc.date.issued2013
dc.identifier.issn0022-1481
dc.identifier.otherht_135_11_111012.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/152264
dc.description.abstractImpinging jets are widely used to achieve a high local convective heat flux, with applications in high power density electronics and various other industrial fields. The heat transfer to steady impinging jets has been extensively researched, yet the understanding of pulsating impinging jets remains incomplete. Although some studies have shown a significant enhancement compared to steady jets, others have shown reductions in heat transfer rate, without consensus on the heat transfer mechanisms that determine this behavior. This study investigates the local convective heat transfer to a pulsating air jet from a long straight circular pipe nozzle impinging onto a smooth planar surface (nozzletosurface spacing 1 ≤ H/D ≤ 6, Reynolds numbers 6000 ≤ Re ≤ 14,000, pulsation frequency 9 Hz ≤ f ≤ 55Hz, Strouhal number 0.007 ≤ Sr = fD/Um ≤ 0.1). A different behavior is observed for the heat transfer enhancement in (i) the stagnation zone, (ii) the wall jet region and overall area average. Two different modified Strouhal numbers have been identified to scale the heat transfer enhancement in both regions: (i) Sr(H/D) and (ii) SrRe0.5. The average heat transfer rate increases by up to 75–85% for SrRe0.5 ≅ 8 (Sr = 0.1, Re = 6000), independent of nozzletosurface spacing. The stagnation heat transfer rate increases with nozzletosurface distance H/D. For H/D = 1 and low pulsation frequency (Sr < 0.025), a reduction in stagnation point heat transfer rate by 13% is observed, increasing to positive enhancements for Sr(H/D) > 0.1 up to a maximum enhancement of 48% at Sr(H/D) = 0.6.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleScaling of Convective Heat Transfer Enhancement Due to Flow Pulsation in an Axisymmetric Impinging Jet
dc.typeJournal Paper
dc.journal.volume135
dc.journal.issue11
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4024620
dc.journal.fristpage111012
dc.journal.lastpage111012
dc.identifier.eissn1528-8943
dc.treeJournal of Heat Transfer:;2013:;volume( 135 ):;issue: 011
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record