Show simple item record

dc.contributor.authorSupra, Jen
dc.contributor.authorJanأںen, Holger
dc.contributor.authorLehnert, Werner
dc.contributor.authorStolten, Detlef
dc.date.accessioned2017-05-09T00:59:28Z
dc.date.available2017-05-09T00:59:28Z
dc.date.issued2013
dc.identifier.issn2381-6872
dc.identifier.otherfc_010_05_051002.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/152008
dc.description.abstractA 10cell hightemperature polymer electrolyte fuel cell (HTPEFC) stack with an active cell area of 200 cm2 has been built up and tested with regard to the temperature distribution from cell to cell and over the active area since not every cell is cooled. Measurements with artificial reformate as a fuel show that the vertical temperature distribution over the active area is sufficiently small, with a maximum of 5.1 K at 550 mA cm−2. Additionally, the temperature gradient from cell to cell is sufficiently small with 10.7 K at 550 mA cm−2. As a result, it can be concluded that the heat pipe supported external cooling is well suited to cool HTPEFC stacks with large active areas in reformate operation.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleDesign and Experimental Investigation of a Heat Pipe Supported External Cooling System for HT PEFC Stacks
dc.typeJournal Paper
dc.journal.volume10
dc.journal.issue5
dc.journal.titleJournal of Fuel Cell Science and Technology
dc.identifier.doi10.1115/1.4025052
dc.journal.fristpage51002
dc.journal.lastpage51002
dc.identifier.eissn2381-6910
dc.treeJournal of Fuel Cell Science and Technology:;2013:;volume( 010 ):;issue: 005
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record