Show simple item record

dc.contributor.authorKesana, N. R.
dc.contributor.authorGrubb, S. A.
dc.contributor.authorMcLaury, B. S.
dc.contributor.authorShirazi, S. A.
dc.date.accessioned2017-05-09T00:57:53Z
dc.date.available2017-05-09T00:57:53Z
dc.date.issued2013
dc.identifier.issn0195-0738
dc.identifier.otherjert_135_3_032905.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/151492
dc.description.abstractSolid particle erosion is a mechanical process in which material is removed from a surface due to impacts of solid particles transported within a fluid. It is a common problem faced by the petroleum industry, as solid particles are also produced along with oil and gas. The erosion not only causes economic losses resulting from repairs and decreased production but also causes safety and environmental concerns. Therefore, the metal losses occurring in different multiphase flow regimes need to be studied and understood in order to develop protective guidelines for oil and gas production equipment. In the current study, a novel noninvasive ultrasonic (UT) device has been developed and implemented to measure the metal loss at 16 different locations inside an elbow. Initially, experiments were performed with a singlephase carrier fluid (gassand) moving in the pipeline, and the erosion magnitudes are compared with computational fluid dynamics (CFD) results and found to be in good agreement. Next, experiments were extended to the multiphase slug flow regime. Influence of particle diameter and liquid viscosity were also studied. Two different particle sizes (150 and 300 خ¼m sand) were used for performing tests. The shapes of the sand are also different with the 300 خ¼m sand being sharper than the 150 خ¼m sand. Three different liquid viscosities were used for the present study (1 cP, 10 cP, and 40 cP). While performing the UT experiments, simultaneous metal loss measurements were also made using an intrusive electrical resistance (ER) probe in a section of straight pipe. The probe in the straight pipe is an anglehead probe which protrudes into the flow with the face placed in the center of the pipe. The UT erosion measurements in a bend are also compared with experimental data obtained placing an intrusive flat head ER probe flush in a bend, and the results were found to be in good agreement. Finally, the noninvasive nano UT permanent placement temperature compensated ultrasonic wall thickness device developed for this work has the capability of measuring metal loss at many locations and also identifying the maximum erosive location on the pipe bend.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleUltrasonic Measurement of Multiphase Flow Erosion Patterns in a Standard Elbow
dc.typeJournal Paper
dc.journal.volume135
dc.journal.issue3
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.4023331
dc.journal.fristpage32905
dc.journal.lastpage32905
dc.identifier.eissn1528-8994
dc.treeJournal of Energy Resources Technology:;2013:;volume( 135 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record