Show simple item record

dc.contributor.authorThompson, Dakotah R.
dc.contributor.authorRao, Sameer R.
dc.contributor.authorCola, Baratunde A.
dc.date.accessioned2017-05-09T00:57:44Z
dc.date.available2017-05-09T00:57:44Z
dc.date.issued2013
dc.identifier.issn1528-9044
dc.identifier.otherep_135_04_041002.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/151441
dc.description.abstractA steppedbar apparatus has been designed and constructed to characterize the thermal resistance of materials using steadystate heat transfer techniques. The design of the apparatus is a modification of the ASTM D5470 standard where reference bars of equal crosssectional area are used to extrapolate surface temperatures and heat flux across a sample of unknown thermal resistance. The design modification involves intentionally oversizing the upper reference bar (URB) of the apparatus to avoid contact area uncertainty due to reference bar misalignment, which is difficult to account for, as well as the high cost that can be associated with equipping the apparatus with precise alignment controls (e.g., pneumatic alignment). Multidimensional heat transfer in the upper reference bar near the sample interface is anticipated using numerical modeling. The resulting nonlinear temperature profile in the upper reference bar is accounted for by fitting a second order regression line through thermocouple readings near the sample interface. The thermal resistances of commercially available thermal gap pads and thermal pastes were measured with the steppedbar apparatus; the measured values were in good agreement with published results, and exhibited a high degree of reproducibility. The measurement uncertainty of both the standard and steppedbar apparatus decrease with increased thermocouple precision. Notably, the uncertainty due to reference bar misalignment with the standard apparatus becomes more pronounced as thermocouple precision and the number of thermocouples increases, which suggests that the steppedbar apparatus would be especially advantageous for enabling accurate, highprecision measurements of very low thermal resistances.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleA Stepped Bar Apparatus for Thermal Resistance Measurements
dc.typeJournal Paper
dc.journal.volume135
dc.journal.issue4
dc.journal.titleJournal of Electronic Packaging
dc.identifier.doi10.1115/1.4025116
dc.journal.fristpage41002
dc.journal.lastpage41002
dc.identifier.eissn1043-7398
dc.treeJournal of Electronic Packaging:;2013:;volume( 135 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)