dc.description.abstractThis paper expands on the work presented by Demetriou and Khalifa (Demetriou and Khalifa, 2013, “Thermally Aware, EnergyBased Load Placement in OpenAisle, AirCooled Data Centers,â€‌ ASME J. Electron. Packag., 135(3), p. 030906) that investigated practical IT load placement options in openaisle, aircooled data centers. The study found that a robust approach was to use realtime temperature measurements at the inlet of the racks to remove IT load from the servers with the warmest inlet temperature. By considering the holistic optimization of the data center load placement strategy and the cooling infrastructure optimization, for a range of data center IT utilization levels, this study investigated the effect of ambient temperatures on the data center operation, the consolidation of servers by completely shutting them off, a complementary strategy to those presented by Demetriou and Khalifa (Demetriou and Khalifa, 2013, “Thermally Aware, EnergyBased Load Placement in OpenAisle, AirCooled Data Centers,â€‌ ASME J. Electron. Packag., 135(3), p. 030906) for increasing the IT load beginning with servers that have the coldest inlet temperature and finally the development of load placement rules via either static (i.e., during data center benchmarking) or dynamic (using realtime data from the current thermal environment) allocation. In all of these case studies, by using a holistic optimization of the data center and associated cooling infrastructure, a key finding has been that a significant amount of savings in the cooling infrastructure's power consumption is seen by reducing the CRAH's airflow rate. In many cases, these savings can be larger than providing higher temperature chilled water from the refrigeration units. Therefore, the path to realizing the industry's goal of higher IT equipment inlet temperatures to improve energy efficiency should be through both a reduction in air flow rate and increasing supply air temperatures and not necessarily through only higher CRAH supply air temperatures.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleExpanded Assessment of a Practical Thermally Aware Energy Optimized Load Placement Strategy for Open Aisle, Air Cooled Data Centers
dc.typeJournal Paper
dc.journal.volume135
dc.journal.issue3
dc.journal.titleJournal of Electronic Packaging
dc.identifier.doi10.1115/1.4024945
dc.journal.fristpage30907
dc.journal.lastpage30907
dc.identifier.eissn1043-7398
dc.treeJournal of Electronic Packaging:;2013:;volume( 135 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record