dc.description.abstractThis paper introduces a methodology for developing a reduced order model, using proper orthogonal decomposition (POD), to predict the IT rack's inlet temperature distribution within a raised floor aircooled data center. The method used in this paper uses a limited set of computational fluid dynamics data at different useful IT levels and tile airflow fractions. The model was able to reconstruct these datasets to with 0.16 آ°C rms error and interpolate successfully for alternative configurations that were not included in the original dataset. The reduced order model can produce the temperature distribution in the data center in a fraction of a second on a standard personal computer. Several practical IT load placement options in openaisle, aircooled data centers, based on either geometrical traits of the data center, a prior physicsbased knowledge of the airflow and temperature patterns or measurements that are easily obtainable during operation, are considered. The outcome of this work is the development of a robust set of guidelines that facilitate the energy efficient placement of the IT load amongst the operating servers in the data center. This work found that a robust approach was to use realtime temperature measurements at the inlet of the racks to remove the unnecessary IT load from the servers with the warmest inlet temperature. This strategy shows superior performance to the other strategies studied. The study considered the holistic optimization of the data center and cooling infrastructure for a range of data center IT utilization levels. The results showed that allowing for significant reductions in the supply air flow rate proved superior to providing a higher supply air temperature to meet the IT equipment's inlet air temperature constraint.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleThermally Aware, Energy Based Load Placement in Open Aisle, Air Cooled Data Centers
dc.typeJournal Paper
dc.journal.volume135
dc.journal.issue3
dc.journal.titleJournal of Electronic Packaging
dc.identifier.doi10.1115/1.4024946
dc.journal.fristpage30906
dc.journal.lastpage30906
dc.identifier.eissn1043-7398
dc.treeJournal of Electronic Packaging:;2013:;volume( 135 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record