    Computational and Experimental Validation of a Vortex Superposition Based Buoyancy Approximation for the COMPACT Code in Data Centers

    Thumbnail
    View/Open
    ep_135_03_030903.pdf (2.364Mb)
    Date
    2013
    Author
    Lettieri, David J.
    Toulouse, Michael M.
    Bash, Cullen E.
    Shah, Amip J.
    Carey, Van P.
    Metadata
    Show full item record
    Abstract
    A simplified model and GUI package, named COMPACT (Compact Model of Potential Flow and Convective Transport), has been developed in previous years to provide a fast alternative to full computational fluid dynamic (CFD) thermofluidic models for a variety of data center applications. These include, but are not limited to, use as a firstorder design tool, a potential improvement to plantbased controllers, and an initial guess for complex CFD solvers. COMPACT applies convective energy transport equations to a computed potential flow field to approximate a flow and temperature field, taking 30 s or less for a commercially available laptop to characterize a 7700 cell room. Previously, the results from this model were compared to experimental measurements taken from a data center at HewlettPackard Laboratories (HP Labs) in Palo Alto, CA. High localized temperatures in the model led to the conclusion that recirculation and buoyancy were contributing excessively to error in the model. This paper proposes a method of vortex superposition to account for these effects, in which locations with high temperature in the original model are analyzed and a corrective flow field consisting of Rankine vortices is superimposed on the solution. This approach is tested with further experimental measurements taken from the data center at HP Labs, as well as conventional commercially available CFD. These newer results show a marked decrease in mean deviation of the model from measured temperatures, as well as elimination of the highly localized temperatures which afflicted the original COMPACT results. The vortex superposition model is also “tuned,â€‌ with vortex strength optimized for multiple test cases at varying levels of recirculation.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/151425
    Collections
    • Journal of Electronic Packaging

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV