    A New Method to Design Robust Power Oscillation Dampers for Distributed Synchronous Generation Systems

    Thumbnail
    View/Open
    ds_135_3_031011.pdf (691.3Kb)
    Date
    2013
    Author
    Kuiava, Roman
    Ramos, Rodrigo A.
    Pota, Hemanshu R.
    Metadata
    Show full item record
    Abstract
    This paper presents a new methodology for the design of power oscillation dampers (PODs) for synchronous generators connected to distribution networks. The proposed methodology provides controllers capable of fulfilling robustness requirements and also making an effective tradeoff between oscillation damping enhancement and generator terminal voltage performance. A description of the nonlinear dynamical model to be controlled in the form of normbounded linear differential inclusions (NLDIs) is adopted at the design stage of the controller. This is different from most of the existing POD design methods, where the control design is essentially based on a simplification of the nonlinear dynamical model in the form of linear timeinvariant (LTI) models. The use of NLDIs allows us to consider the system nonlinearities as model uncertainties, and then we take into account such uncertainties at the controller design stage using a robust control methodology. Once that this NLDI takes the nonlinear behaviors of the system into account, it can better represent the relatively large excursions that occur in the system states, allowing us to add a constrain to the control problem formulation imposing a certain acceptable performance to the generator terminal voltage during transients. The proposed algorithm can be easily handled by using linear matrix inequalities (LMIs) solvers. A cogeneration plant of 10 MW added to a distribution network constituted by a feeder and six buses is adopted as a test system. The results show that the two designed objectives are quite satisfactorily achieved.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/151299
    Collections
    • Journal of Dynamic Systems, Measurement, and Control

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV