dc.description.abstractLeaks in general and hydraulic leaks in specific are one of the major failure modes for mobile equipment. In-plant leak rates may range from 1% to 25%, while field leaks may range from 1% to 13% depending on the complexity of the system, assembly process, and parts quality. In this paper, the main potential leak causes are discussed and the performance of different types of fittings is compared, including JIC 37 flare fittings, O-ring boss seal, and O-ring face seal. Several potential improvement actions related to assembly process, torque specifications, and quality of manufactured fittings are proposed to reduce leaks. Among the many benefits leak reduction will result in improved customer safety and satisfaction, assembly down time reduction, cost and warranty reduction, and environmental impact reduction.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleFailure Mode Analysis of Mobile Equipment Hydraulic Leaks
dc.typeJournal Paper
dc.journal.volume134
dc.journal.issue3
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.4006342
dc.journal.fristpage34502
dc.identifier.eissn1528-8978
dc.keywordsTorque
dc.keywordsFailure
dc.keywordsFittings
dc.keywordsLeakage
dc.keywordsManufacturing
dc.keywordsIndustrial plants AND Seals
dc.treeJournal of Pressure Vessel Technology:;2012:;volume( 134 ):;issue: 003
dc.contenttypeFulltext