dc.description.abstractIn this paper, an extensometer was specifically designed for online deformation monitoring of high temperature pipes and its applicability was verified experimentally. The design procedure and the installation of the extensometer were described in detail. Experiments were carried out to prove the accuracy and the reliability of the extensometer. The laboratory test at room temperature was performed. The reliability of the extensometer at high temperature was validated by on-site monitoring of the deformation of a main steam pipe operating at 540 °C in a power plant. It was demonstrated that the designed extensometer has a high accuracy and an excellent reliability for measurement of the deformation of the high temperature pipes.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleDesign and Test of an Extensometer for Strain Monitoring of High Temperature Pipelines
dc.typeJournal Paper
dc.journal.volume134
dc.journal.issue4
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.4005943
dc.journal.fristpage44501
dc.identifier.eissn1528-8978
dc.keywordsDeformation
dc.keywordsTemperature
dc.keywordsReliability
dc.keywordsDesign
dc.keywordsPipes
dc.keywordsSteam
dc.keywordsHigh temperature
dc.keywordsSensors
dc.keywordsPipelines
dc.keywordsPower stations AND Stability
dc.treeJournal of Pressure Vessel Technology:;2012:;volume( 134 ):;issue: 004