dc.description.abstractDryout in a heat pipe evaporator is caused by insufficient condensate supply through the wick structure. Dryout is generally considered a failure of the heat pipe operation. However, traditional dryout theory may not fully explain the heat and mass transport limitations in the biporous (biwick) wick structure due to new mass transfer mechanisms, such as liquid splash at high heat flux, and vapor bubble/jet occupation of liquid transport passages. This article investigates the dryout phenomenon in carbon nanotube (CNT) based biwick structure. The incipience and expansion of the dryout zone on the CNT biwick structure are visualized. Variation of the evaporator temperatures at various heat fluxes is measured to characterize the temperature responses on the biwick dryout. Results based on both visualization and measurement show that dryout of CNT biwick structures is affected by vapor flow induced droplet splash and vapor occupation of liquid transport passages, which reduces the liquid supply to the hottest region and creates a local dry zone. On the curves of heat flux versus the evaporator temperature, dryout can be defined as the appearance of the inflexion point during the heating period, and associated with the existence of a large temperature hysteresis in a heating and cooling cycle. Experimental measurement also shows that over 12% of the liquid by volume is lost without being phase changed, due to high-speed vapor flow induced liquid splash. Liquid splash and interactions between vapor and liquid flows also increase the pressure drop weight in the evaporator over the system loop and result in more notable heating area effect on biwick structures when compared with traditional monowick structures.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleInvestigations of Biporous Wick Structure Dryout
dc.typeJournal Paper
dc.journal.volume134
dc.journal.issue2
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4005099
dc.journal.fristpage21503
dc.identifier.eissn1528-8943
dc.keywordsTemperature
dc.keywordsVapors
dc.keywordsCarbon nanotubes
dc.keywordsHeating
dc.keywordsHeat flux
dc.keywordsHeat
dc.keywordsFlow (Dynamics)
dc.keywordsHeat pipes
dc.keywordsBubbles
dc.keywordsVisualization AND Evaporation
dc.treeJournal of Heat Transfer:;2012:;volume( 134 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail
This item appears in the following Collection(s)

Show simple item record