Show simple item record

dc.contributor.authorAdhika Widyaparaga
dc.contributor.authorMasashi Kuwamoto
dc.contributor.authorNaoya Sakoda
dc.contributor.authorMasamichi Kohno
dc.contributor.authorYasuyuki Takata
dc.date.accessioned2017-05-09T00:52:28Z
dc.date.available2017-05-09T00:52:28Z
dc.date.copyrightFebruary, 2012
dc.date.issued2012
dc.identifier.issn0022-1481
dc.identifier.otherJHTRAO-27933#020903_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/149538
dc.description.abstractWe have developed a model capable of predicting the performance characteristics of a wiretype Joule–Thomson microcooler intended for use within a cryosurgical probe. Our objective was to be able to predict cold tip temperature, temperature distribution, and cooling power using only inlet gas properties as input variables. To achieve this, the model incorporated gas equations of state to account for changing gas properties due to heat transfer within the heat exchanger and expansion within the capillary. In consideration of inefficiencies, heat in-leak from free convection and radiation was also considered and the use of a 2D axisymmetric finite difference code allowed simulation of axial conduction. To validate simulation results, we have constructed and conducted experiments with two types of microcoolers differing in inner tube material, poly-ether-ether-ketone (PEEK) and stainless steel. The parameters of the experiment were used in the calculations. CO2 was used as the coolant gas for inlet pressures from 0.5 MPa to 2.0 MPa. Heat load trials of up to 550 mW along with unloaded trials were conducted. The temperature measurements show that the model was successfully able to predict the cold tip temperature to a good degree of accuracy and well represent the temperature distribution. For the all PEEK microcooler in a vacuum using 2.0 MPa inlet pressure, the calculations predicted a temperature drop of 57 K and mass flow rate of 19.5 mg/s compared to measured values of 63 K and 19.4 mg/s, therefore, showing that conventional macroscale correlations can hold well for turbulent microscale flow and heat transfer as long as the validity of the assumptions is verified.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleTheoretical and Experimental Study of a Flexible Wiretype Joule–Thomson Microrefrigerator for Use in Cryosurgery
dc.typeJournal Paper
dc.journal.volume134
dc.journal.issue2
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4004937
dc.journal.fristpage20903
dc.identifier.eissn1528-8943
dc.keywordsPressure
dc.keywordsFlow (Dynamics)
dc.keywordsHeat
dc.keywordsTemperature
dc.keywordsHeat transfer
dc.keywordsJoules
dc.keywordsHeat exchangers
dc.keywordsTemperature distribution
dc.keywordsDrops
dc.keywordsLeakage
dc.keywordsCooling
dc.keywordsVacuum AND Temperature measurement
dc.treeJournal of Heat Transfer:;2012:;volume( 134 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record