Show simple item record

dc.contributor.authorJustin A. Lamont
dc.contributor.authorSrinath V. Ekkad
dc.contributor.authorMary Anne Alvin
dc.date.accessioned2017-05-09T00:52:04Z
dc.date.available2017-05-09T00:52:04Z
dc.date.copyrightAugust, 2012
dc.date.issued2012
dc.identifier.issn0022-1481
dc.identifier.otherJHTRAO-27947#082202_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/149388
dc.description.abstractThe effects of the Coriolis force are investigated in rotating internal serpentine coolant channels in turbine blades. For complex flow in rotating channels, detailed measurements of the heat transfer over the channel surface will greatly enhance the blade designers’ ability to predict hot spots so coolant may be distributed more effectively. The present study uses a novel transient liquid crystal technique to measure heat transfer in a rotating, radially outward channel with impingement jets. A simple case with a single row of constant pitch impinging jets with the crossflow effect is presented to demonstrate the novel liquid crystal technique and document the baseline effects for this type of geometry. The present study examines the differences in heat transfer distributions due to variations in jet Rotation number, Roj , and jet orifice-to-target surface distance (H/dj = 1,2, and 3). Colder air, below room temperature, is passed through a room temperature test section to cause a color change in the liquid crystals. This ensures that buoyancy is acting in a similar direction as in actual turbine blades where walls are hotter than the coolant fluid. Three parameters were controlled in the testing: jet coolant-to-wall temperature ratio, average jet Reynolds number, Rej , and average jet Rotation number, Roj . Results show, such as serpentine channels, the trailing side experiences an increase in heat transfer and the leading side experiences a decrease for all jet channel height-to-jet diameter ratios (H/dj ). At a jet channel height-to-jet diameter ratio of 1, the crossflow from upstream spent jets greatly affects impingement heat transfer behavior in the channel. For H/dj = 2 and 3, the effects of the crossflow are not as prevalent as H/dj = 1: however, it still plays a detrimental role. The stationary case shows that heat transfer increases with higher H/dj values, so that H/dj = 3 has the highest results of the three examined. However, during rotation the H/dj = 2 case shows the highest heat transfer values for both the leading and trailing sides. The Coriolis force may have a considerable effect on the developing length of the potential core, affecting the resulting heat transfer on the target surface.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleEffects of Rotation on Heat Transfer for a Single Row Jet Impingement Array With Crossflow
dc.typeJournal Paper
dc.journal.volume134
dc.journal.issue8
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4006167
dc.journal.fristpage82202
dc.identifier.eissn1528-8943
dc.keywordsRotation
dc.keywordsFlow (Dynamics)
dc.keywordsHeat transfer
dc.keywordsChannels (Hydraulic engineering)
dc.keywordsCoolants
dc.keywordsJets
dc.keywordsTemperature
dc.keywordsCoriolis force AND Liquid crystals
dc.treeJournal of Heat Transfer:;2012:;volume( 134 ):;issue: 008
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record