Show simple item record

dc.contributor.authorSin Chien Siw
dc.contributor.authorTom I.-P. Shih
dc.contributor.authorMary Anne Alvin
dc.contributor.authorMinking K. Chyu
dc.date.accessioned2017-05-09T00:52:03Z
dc.date.available2017-05-09T00:52:03Z
dc.date.copyrightAugust, 2012
dc.date.issued2012
dc.identifier.issn0022-1481
dc.identifier.otherJHTRAO-27947#081902_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/149386
dc.description.abstractHeat transfer and pressure characteristics in a rectangular channel with pin-fin arrays of partial detachment from one of the endwalls have been experimentally studied. The overall channel geometry (W = 76.2 mm, E = 25.4 mm) simulates an internal cooling passage of wide aspect ratio (3:1) in a gas turbine airfoil. With a given pin diameter, D = 6.35 mm = ¼E, three different pin-fin height-to-diameter ratios, H/D = 4, 3, and 2, were examined. Each of these three cases corresponds to a specific pin array geometry of detachment spacing (C) between the pin tip and one of the endwalls, i.e., C/D = 0, 1, 2, respectively. The Reynolds number, based on the hydraulic diameter of the unobstructed cross-section and the mean bulk velocity, ranges from 10,000 to 25,000. The experiment employs a hybrid technique based on transient liquid crystal imaging to obtain the distributions of the local heat transfer coefficient over all of the participating surfaces, including the endwalls and all the pin elements. Experimental results reveal that the presence of a detached space between the pin tip and the endwall has a significant effect on the convective heat transfer and pressure loss in the channel. The presence of pin-to-endwall spacing promotes wall-flow interaction, generates additional separated shear layers, and augments turbulent transport. In general, an increase in detached spacing, or C/D, leads to lower heat transfer enhancement and pressure drop. However, C/D = 1, i.e., H/D = 3, of a staggered array configuration exhibits the highest heat transfer enhancement, followed by the cases of C/D = 0 and C/D = 2, i.e., H/D = 4 or 2, respectively.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleEffects of Pin Detached Space on Heat Transfer and Pin-Fin Arrays
dc.typeJournal Paper
dc.journal.volume134
dc.journal.issue8
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4006166
dc.journal.fristpage81902
dc.identifier.eissn1528-8943
dc.keywordsPressure
dc.keywordsHeat transfer
dc.keywordsHeat transfer coefficients
dc.keywordsChannels (Hydraulic engineering)
dc.keywordsFlow (Dynamics)
dc.keywordsPins (Engineering)
dc.keywordsClearances (Engineering)
dc.keywordsFins
dc.keywordsShear (Mechanics) AND Turbulence
dc.treeJournal of Heat Transfer:;2012:;volume( 134 ):;issue: 008
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record