dc.description.abstractThis work describes the experimental setup, method, and results of utilizing a micrometer to move an adjustable orifice immediately in front of an array of microchannels. Research by others indicates potential for significant improvement in delaying critical heat flux and increasing heat transfer coefficients when placing an orifice in front of each individual channel of a microchannel array. The experimental setup in this work allows incremental orifice size changes. This ability allows the experimentalist to find which orifice size provides enough pressure drop immediately in front of the channels to reduce oscillations. The design also allows for rapid change of orifice size without having to remove and replace any components of the test setup. Signal analysis methods were used to identify frequency and amplitude of pressure and temperature oscillations. Low mass flux experiments (300 kg m−2 s−1 and 600 kg m−2 s−1 of R134a in a pumped loop) showed reduced channel wall temperatures with smaller orifice sizes. The orifice concept was found to be effective at reducing oscillations for the higher 600 kg m−2 s−1 flow rate, but the data indicate that wall temperature reduction with inlet orifice use is not solely due to elimination of oscillations. Signal analysis was an effective method of identifying oscillations without the availability of pictorial representation of flow patterns in the channels.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleMicrochannel Two-Phase Flow Oscillation Control With an Adjustable Inlet Orifice
dc.typeJournal Paper
dc.journal.volume134
dc.journal.issue12
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4007202
dc.journal.fristpage122901
dc.identifier.eissn1528-8943
dc.keywordsOscillations
dc.keywordsPressure
dc.keywordsFlow (Dynamics)
dc.keywordsTemperature
dc.keywordsChannels (Hydraulic engineering)
dc.keywordsPressure drop
dc.keywordsWall temperature
dc.keywordsMicrochannels
dc.keywordsRefrigerants
dc.keywordsHeat
dc.keywordsTwo-phase flow
dc.keywordsDams AND Steady state
dc.treeJournal of Heat Transfer:;2012:;volume( 134 ):;issue: 012
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record