Evaluation of Methods for Thermal Management in a Coal-Based SOFC Turbine Hybrid Through Numerical Simulation
View/ Open
Date
2012Author
David Tucker
J. Christopher Ford
Comas Haynes
John VanOsdol
Eric Liese
Larry Lawson
Stephen Zitney
Randall Gemmen
Metadata
Show full item recordAbstract
Managing the temperatures and heat transfer in the fuel cell of a solid oxide fuel cell (SOFC) gas turbine (GT) hybrid fired on coal syngas presents certain challenges over a natural gas based system, in that the latter can take advantage of internal reforming to offset heat generated in the fuel cell. Three coal based SOFC/GT configuration designs for thermal management in the main power block are evaluated using steady state numerical simulations developed in ASPEN PLUS. A comparison is made on the basis of efficiency, operability issues and component integration. To focus on the effects of different power block configurations, the analysis assumes a consistent syngas composition in each case, and does not explicitly include gasification or syngas cleanup. A fuel cell module rated at 240 MW was used as a common basis for three different methods. Advantages and difficulties for each configuration are identified in the simulations.